bcmxcp
XXX
XXX WARNING: old character encoding and/or character set
XXX
BCMXCP(8) Network UPS Tools (NUT) BCMXCP(8)
NAME
bcmxcp - Driver for UPS’es supporting the BCM/XCP protocol
NOTE
This man page only documents the hardware-specific features of the
bcmxcp driver. For information about the core driver, see nutups-
drv(8).
SUPPORTED HARDWARE
This driver should recognize all BCM/XCP-compatible UPS’es. It has
been developed and tested on Powerware PW5115 and PW9120 hardware.
EXTRA ARGUMENTS
This driver supports the following optional settings in the
ups.conf(5).
shutdown_delay=delay
The number of seconds that the UPS should wait between receiving
the shutdown command and actually shutting off.
DEFAULT VALUES FOR THE EXTRA ARGUMENTS
shutdown_delay = 180
INSTANT COMMANDS
This driver supports the following Instant Commands:
shutdown.return
Turn off the load and return when power is back.
shutdown.stayoff
Turn off the load and remain off.
test.battery.start
Start a battery test.
TODO LIST
Report UPS alarm status
BCM/XCP supports reporting a wide range of UPS alarm conditions.
Report UPS statistics informations
BCM/XCP supports reporting of UPS statistics data.
BUGS
None known.
AUTHOR
Tore Ørpetveit <tore@orpetveit.net>
SEE ALSO
The core driver:
nutupsdrv(8)
Internet resources:
The NUT (Network UPS Tools) home page: http://www.networkupstools.org/
Sun Sep 19 2004 BCMXCP(8)
Man(1) output converted with
man2html